Four Test are required for each PV Vent Cap
VC Tester Brochure
Pressure Test
1. Positive Leak Rate Test at 2.0” w.c.
Measures how much air (vapor) can leak past the valve when there’s a very low amount of pressure
2. Positive Cracking Pressure at 120 ml/min
Measures the amount of pressure it takes to cause the valve to “open” up. After the valve “cracks” it won’t hold quite as much pressure.
Vacuum Test
3. Negative Leak Rate Test at -4.0” w.c.
Measures how much air (vapor) can leak past the valve when there’s a very low amount of vacuum.
4. Negative cracking pressure at 200 ml/min
Measures the amount of vacuum it takes to cause the valve to “open” up when the vacuum is building up. After the valve “cracks” it won’t hold as much vacuum.